42
11.5 Word Zone - Page 3 Program
Address
Modbus JbuS Variable Parameter
code
Type
64 65 Program status
Stat
R/W
8
65 66 Restart after a power OFF
FaiL
R/W
9
66 67 Time units
Unit
R/W
10
67 68 Number of segments
n.Seg
R/W
68 69 Number of program cycles
Cyc.
R/W
69 70 Allowed deviation
band
R/W
70 71 Segment “0” time
ti. 0
R/W
71 72 Segment “0” Setpoint
S.P. 0
R/W
72 73 Segment “0” OP3 digital output
dO. 0
R/W
20
73 74 Segment “1” time
ti. 1
R/W
74 75 Segment “1” Setpoint
S.P. 1
R/W
75 76 Segment “1” OP3 digital output
dO. 1
R/W
20
76 77 Segment “2” time
ti. 2
R/W
77 78 Segment “2” Setpoint
S.P. 2
R/W
78 79 Segment “2” OP3 digital output
dO. 2
R/W
20
79 80 Segment “3” time
ti. 3
R/W
80 81 Segment “3” Setpoint
S.P. 3
R/W
81 82 Segment “3” OP3 digital output
dO. 3
R/W
20
82 83 Segment “4” time
ti. 4
R/W
83 84 Segment “4” Setpoint
S.P. 4
R/W
84 85 Segment “4” OP3 digital output
dO. 4
R/W
20
85 86 Segment “5” time
ti. 5
R/W
86 87 Segment “5” Setpoint
S.P. 5
R/W
87 88 Segment “5” OP3 digital output
dO. 5
R/W
20
88 89 Segment “6” time
ti. 6
R/W
89 90 Segment “6” Setpoint
S.P. 6
R/W
90 91 Segment “6” OP3 digital output
dO. 6
R/W
20
91 92 Segment “End” Setpoint
S.P. F
R/W
92 93 Segment “End” OP3 digital output
dO. F
R/W
20
93..99 94..100 -
-
-
11.6 Word Zone - Page 4 Configuration
Address
Modbus JbuS Variable Parameter
code
Type
100 101 Remote Setpoint range
rS.In
R/W
5/11
101 102 1° version configuration
Con.1
R/W
5
102 103 2° version configuration
Con.2
R/W
5
103 104 Engineering units
unit
R/W
5/12
104 105 Number of decimals
Sc.d.d
R/W
5
105 106 Low range
Sc.Lo
R/W
5
106 107 High range
Sc.Hi
R/W
5
107 108 Communications protocol
Prot
R/W
13
108 109 Baud rate
baud
R/W
14
109 110 Continuous control output range
retr
R/W
15
110 111 Retransmission output selection
rtH
R/W
16